VoltNomad Off-Grid Electrical Field Designer

Off-Grid Solar, Van & Marine Electrical Sizing Designer

Audit daily DC/AC loads, size LiFePO4 or AGM banks, generate a live color-coded SVG wiring diagram, verify ABYC copper wire gauges, and export a printable PDF blueprint + BOM.

System Architecture Parameters

12V · LIFEPO4
System Voltage12V
Battery ChemistryLiFePO4 (85% DoD)
Peak Sun Hours (PSH)4 PSH
Days of Autonomy2 days

Daily Appliance Load Audit

AC loads automatically include 12% pure-sine inverter conversion loss (88% efficiency).

Appliance / Load Bus Watts Hrs/Day Qty DC Wh/Day
12V Compressor Fridge (85L) DC 45W 9h 1 405
MaxxAir Roof Exhaust Fan DC 24W 6h 1 144
12V Recessed LED Lights DC 18W 4h 1 72
Starlink Mini / Dishy DC DC 35W 6h 1 210
Diesel Air Heater (2kW) DC 22W 6h 1 132
Induction Cooktop (Single Burner) AC 1400W 0.5h 1 795
Laptop & USB-C External Monitor AC 65W 5h 1 369
Espresso / Coffee Maker AC 950W 0.2h 1 216
Total Daily DC Demand 2,344 Wh (195.3 Ah @ 12V)

Real-Time Sized Off-Grid Architecture

Daily Energy Audit
2,344 Wh
195.3 Ah @ 12V
Recommended Battery Bank
500Ah · 6 kWh
5× 12V 100Ah LiFePO4
Solar Array Sizing
800 W
4× 200W (2S2P)
MPPT Charge Controller
150V / 85A
Victron SmartSolar 150/85 Tr
Pure Sine Inverter
2000 W
Max DC: 189.4A · Class-T 250A
DC-DC & Power Station Match
50A DC-DC
All-in-One Equiv.: EcoFlow DELTA Pro Ultra / Bluetti AC500 + 2×B300S

Auto-Generated Color-Coded System Wiring Diagram

OFF-GRID SYSTEM WIRING SCHEMATIC 12V LiFePO4 | 500Ah (6 kWh) | 800W PV | 2000W AC POSITIVE BUSBAR (+) — 300A NEGATIVE BUSBAR (-) — 300A PV ISOLATOR 25A 2-Pole 12 AWG/4mm² SOLAR PV ARRAY 800W (4×200W) 2S2P · Vmp 40.8V · Imp 19.6A Voc 48.6V (Max 55.9V) 4.5m · ΔV 2.25% MPPT CONTROLLER 150V / 85A MPPT 12V DC · Max 66.7A 6 AWG (16 mm²) MIDI 100A · ΔV 2.16% 100A MIDI 6 AWG 225A ANL/MEGA 1 AWG 50 mm² · 1.92% PURE SINE INVERTER 2000W (4000W) Max DC: 189.4A @ 12V 1 AWG (50 mm²) 1.5m · η 88% AC OUTLETS 120V AC 1215 Wh/d CLASS-T FUSE 250A (20kA AIC) KILL SWITCH 300A ON/OFF SMARTSHUNT 500A 1/0 AWG (50 mm²) BATTERY BANK (LiFePO4) 12V · 500Ah · 6 kWh 5× 12V 100Ah LiFePO4 1/0 AWG (50 mm²) · M8 / 5/16" 70A MIDI DC-DC ALTERNATOR 50A (+552 Wh/h) 2 AWG (35 mm²) 2× 70A MIDI · 4.5m STARTER BATT (12V) 12V + 70A MIDI 15A MIDI 12V DC FUSE BLOCK 12× ATO/ATC · 15A 12 AWG (4 mm²) · ΔV 2.08% 12V DC LOADS: 963 Wh/d 12V DC · LED · Starlink · USB-C DC Positive (+) DC Negative (-) Solar PV Input AC Output Overcurrent Fuse SOLARWIRECALC.COM · ABYC E-11 <= 3% V-DROP

ABYC / NEC Wire Gauge & Voltage Drop Calculator

Computes exact copper AWG & metric mm² checking both 105°C ampacity and round-trip voltage drop.

Minimum Copper AWG
1 AWG
Metric Cross-Section
50 mm²
Actual Voltage Drop2.44% (0.293V)
Recommended Fuse225 A

Circuit Wire & Fuse Protection Schedule

Circuit Path Current 1-Way Run AWG / mm² Cable V-Drop % Fuse Protection
Battery Bank → Main Busbar 199A @ 12V 1 m 1/0 AWG (50 mm²) 1.07% (25.5W) 250A Class-T
Main Busbar → Pure Sine Inverter 189.4A @ 12V 1.5 m 1 AWG (50 mm²) 1.92% (43.7W) 225A ANL / Mega
Roof Solar Array → MPPT Input 19.6A @ 40.8V 4.5 m 12 AWG (4 mm²) 2.25% (18W) 25A PV 2-Pole Breaker / MC4 Fuse
MPPT Output → Main Busbar 66.7A @ 12V 1.5 m 6 AWG (16 mm²) 2.16% (17.3W) 100A MIDI
Main Busbar → 12V DC Fuse Block 12A @ 12V 2 m 12 AWG (4 mm²) 2.08% (3W) 15A MIDI
Starter Battery → DC-DC Charger → Busbar 50A @ 12V 4.5 m 2 AWG (35 mm²) 1.92% (11.5W) 70A MIDI

Complete Bill of Materials (BOM)

Category Component Calculated Rating & Specification Qty Est. USD Installation & Lug Notes
Storage House Battery Bank 5× 12V 100Ah LiFePO4 (6 kWh, 85% DoD) 5 pcs $1,440 LiFePO4 requires low-temp BMS cutoff (<0°C); AGM requires ventilation
Solar PV Monocrystalline Solar Panels 200W Monocrystalline (2S2P — 800W total, 48.6V Voc) 4 pcs $540 Include roof brackets / rail mounts & waterproof cable entry gland
Solar PV MPPT Solar Charge Controller Victron SmartSolar 150/85 Tr (150V / 85A) 1 pcs $440 Verify array Cold Voc stays safely below MPPT voltage ceiling
Conversion Pure Sine Wave Inverter 2000W Pure Sine (4000W Surge), 12V DC → 120V AC 1 pcs $560 Mount within 1.5–2.0m of main busbar using hydraulic-crimped lugs
Conversion DC-DC Alternator Battery Charger Victron Orion XS 12/12-50A / Renogy 50A DC-DC (+552 Wh/hr driving) 1 pcs $310 Install MIDI/MRBF fuses at both starter battery & house busbar ends
Safety & Monitoring 500A Smart Battery Shunt Monitor 500A Bluetooth Battery Monitor (Victron SmartShunt 500A/50mV) 1 pcs $130 Wire directly on main battery negative before the negative busbar
Safety & Monitoring Main Class-T Fuse & Holder 250A Class-T Fuse + Heavy-Duty Holder (20,000A AIC) 1 set $78 Mount within 18 cm (7 in) of main LiFePO4 battery positive post
Safety & Monitoring Master Battery Disconnect Switch 300A Continuous Master Battery Disconnect Switch (Blue Sea m-Series / e-Series) 1 pcs $42 Install inline immediately downstream of the Class-T main fuse
Safety & Monitoring Positive & Negative Copper Busbars Pair (+ Red / - Black) 300A Tin-Plated Copper Busbars w/ Cover (or Victron Lynx Distributor) 1 set $75 Use insulated protective covers on M8 / M10 tin-plated copper studs
Safety & Monitoring 12-Circuit DC Blade Fuse Block 12-Circuit ATO/ATC Blade Fuse Block w/ Negative Bus (Blue Sea 5026) 1 pcs $48 12-circuit ATO/ATC blade distribution protected by upstream MIDI fuse
Safety & Monitoring PV Isolator Breaker & Branch Fuses 25A 2-Pole DC Isolator Breaker (DIN rail) + Inline Fuses (100A MPPT, 225A Inverter) 1 set $65 2-pole DC PV isolator enables safe manual disconnect before servicing
Marine Cabling Heavy-Duty Marine Battery/Inverter Cable 1/0 AWG (50 mm²) Marine Tinned Copper Red+Black (M8 / 5/16" lugs) 6 m $84 ABYC 105°C marine tinned copper red/black (<3% round-trip drop)
Marine Cabling UV Solar PV & MPPT Cabling 12 AWG (4 mm²) UV-Resistant PV Wire + MC4 Connectors + 6 AWG (16 mm²) MPPT-to-Busbar 13 m $52 UV-stabilized outdoor solar PV cable + genuine MC4 connectors
Marine Cabling Tinned Copper Ring Lugs & Heat Shrink Kit Tinned Copper Ring Lugs (M8 / 5/16", M8 / 5/16") + 3:1 Dual-Wall Heat Shrink 1 set $38 Heavy-wall tinned copper lugs + 3:1 adhesive-lined heat shrink
Estimated DIY Material Budget $3,902 12V · 6 kWh · 800W PV

How VoltNomad Sizes Complete Off-Grid Electrical Systems

Off-Grid Electrical Engineering Reference

Every real-world off-grid build begins with an honest Watt-hour (Wh/day) load audit. Direct 12V DC loads like compressor fridges, MaxxAir roof fans, diesel heaters, and Starlink Mini draw directly from the battery bus, whereas 120V/230V AC appliances incur a 12% pure-sine inverter conversion overhead (88% efficiency).

VoltNomad applies exact copper resistivity physics (0.01724 Ω·mm²/m) alongside ABYC E-11 105°C ampacity tables to select the safest minimum AWG & metric mm² conductor for every circuit, pairing LiFePO4 banks with mandatory 20,000A AIC Class-T main fuses.

Typical Off-Grid Rig Architecture Benchmarks (LiFePO4, 3-Season 4.0 PSH)

Off-Grid Build ProfileDaily EnergyBattery BankRoof Solar ArrayPure Sine Inverter
Weekend Camper Van (No Induction)900–1,200 Wh/d12V 200Ah (2.56 kWh)400W (2×200W)1000W – 1500W
Full-Time Sprinter / Transit + Induction2,200–2,800 Wh/d12V 400Ah / 24V 200Ah600W – 800W + 50A DC-DC2000W – 3000W
Cruising Sailboat (Autopilot + Fridge)2,000–3,000 Wh/d24V 300Ah (7.68 kWh)800W – 1000W Arch2000W – 3000W
Year-Round Off-Grid Cabin / Backup4,500–6,000 Wh/d48V 300Ah (15.36 kWh)1600W – 2400W Ground4000W – 5000W

Technical Frequently Asked Questions

Why does the calculator add 12% extra energy to AC inverter appliances?

Pure sine wave inverters convert DC battery voltage into 120V/230V AC at roughly 85%–90% real-world efficiency. Dividing raw AC Watt-hours by 0.88 ensures your battery bank and solar panels cover true DC energy drawn from the terminals.

Why is a Class-T fuse mandatory on LiFePO4 battery banks?

Lithium iron phosphate cells have ultra-low internal resistance and can deliver thousands of short-circuit amps instantaneously. Standard ANL or MIDI fuses can arc weld shut; Class-T fuses offer a 20,000A interrupt rating (AIC) to safely clear catastrophic faults.

How many Peak Sun Hours (PSH) should I pick for solar sizing?

Use 5.5 PSH for sunny summer travel, 4.0 PSH for balanced 3-season camping, and 2.2 PSH for winter snow-chasing or high-latitude regions where flat roof panels lose low-angle output.

Popular Wattage Starter Blueprints

Specialized Off-Grid Calculators & Guides